21
Reinstall covers.
15.2 Pump Replacement
1
Trip sheer valve.
2
Lower the internal pressure by shutting down remote pump and activate unit by lifting the
nozzle.
3
Loosen the fittings on the pump tubes and disconnect tubes. Fig 15.20.
Figure 15.20: Loosen fittings
4
Use 2.5 mm Allen wrench and remove three screws on pump and pull pump from motor.
5
Install new pump in reverse order.
6
Reset sheer valve
7
Power up and test operation