Sign in (”ENTER” , password, ”ENTER”)b.
Press ”UP” until the display shows ”o ---”.c.
Press ”757”,”ENTER”,”ENTER”d.
The display will now toggle between ”o 757” och ”.000”
Press ”NEXT” until UP display shows ”.004”.e.
Press”#” followed by the nod-number to be filled (on C34-344 A1 node#1
and node#2 are used). Then press ”ENTER”.
f.
For example ”#”, ”1”,”ENTER” to start additive pumping on node #1.
The display shows ”PUrGE” and the total amout of liquid pumped in the numer
of 1/10 ml pulses. When there is liquid in a steady flow (no foam) from the
tube, press "ENTER" to stop the flow.
g.
The display shows ”TotAL” and the total amount of liquid pumped in number
of 1/10 ml pulses.
Repeat the procedure for all nodes.h.
Connect the flex pipes.5.
Set the service switch to mode 1.6.
Perform some additive deliveries in order to check that there are not leakages.
Check specially:
7.
•
The bottom of the tank
•
At the flex pipes connection to the solenoid
valve
•
At the flex pipes connection to the iMeter
•
Connecton to filters and pumps