8
Remove product tube lock pin from valve and remove tube from valve. (B)
B
Check valve retaining ring screws
Proportional valve retaining bracket
screws
NOTE:
Proportional valve bracket screws are no
longer than the two check valve retaining
screws.
Be sure to use the correct screws when
reinstalling.
9
Using a 10 mm open end wrench, loosen the (2) hex head screws securing the valve retaining
bracket to the meter, and rotate retaining plate upward. (C) Note: On iMeter2, the two hex
socket head screws are on a diagonal, therefore, rotate valve as needed to access one of
the screws at a time.
10
Pull valve out from meter. (C)
C
Proportional valve retaining bracket
11
Continue with the steps below to change the proportional valve. To change the check valve,
see instructions in the Check Valve Replacement section.
12
Install new o-ring on new valve and on product tube, then lubricate with petroleum jelly.
13
Install new valve into meter and resecure valve retaining bracket.
14
Reinstall tube into valve and reinstall the lock pin.