2
Cut and remove the seal wires on both calibration doors on the WIP.
3
Remove the WIP from the meter and move WIP aside. The WIP cable does not need to be
disconnected.
A
Dome
WIP
Cylinder
Cover
4
Remove the (8) 5 mm hex socket head screws that secure the meter dome to the meter. (B)
Note: There is no need to remove the proportional valve. Photos below are shown without
valve for clarity.
B
Screws (8)
WM048523 Rev 08 01/2019 321