See Fig 6.15 for iMeter and Fig 6.16 for Xflo meter.
1
Remove the (2) 5 mm screws that secure the valve cover to the meter dome and remove the
valve cover.
2
Remove the check valve (and o-ring) from the meter.
3
Install new valve and new o-ring.
Note!
Seat valve fully by hand before re-installing the valve cover. Do not pinch the o-ring against
the meter.
4
Re-install the valve cover with the (2) screws.
(Black Case)
Figure 6.15: iMeter replaceable parts
WM048523 Rev 08 01/2019 93
6 Replacement Procedures