7.3 Drinks setting
7.3.1 Drinks setting
Drinks setting
Can modify the parameters of any beverageFor example: Espresso
Grounds
Grinding gram levelsetting level:15,details as below
The weight of this data is calculated according to the “factory default setting. The data is the experimental value for reference only. If the difference is subject to actual
conditions.
Tolerance
±
1g
F11&F09
Grounds 1 2 3 4 5
Gram 7g 10g 12g 14g 16g
Coffee
ml
The amount of coffee flowing out, unit :ml. setting level:
See the screen numerical on the interface, different beverage with different beverage value limits.
Grinder
Selection: left, right or both
F11with one grinder without selection.
Temp. level
Different temperature level, selection: Low ,Medium, High.
High
Making coffee the water temperature controls at 93~95
℃;
Medium
3
lower than high temperature
Low
3
lower than medium temperature.
Pre-brewing
s
The coffee powder pre-soaking time, unit: S, setting level:15.
Test
After changing the data , touch “test”, make one drinks based on the setting data.
Save
After changing data, touch “save” to save all the changes.
Exit
Touch “Exit” back to upper menu.