REV1.0
Dr.coffee Service Manual 16
7.3 Drinks setting
7.3.1 Drinks setting
Drinks setting:
Can modify the parameters of any beverage(For example: Espresso)
Grounds
Grinding gram level,setting level:1~5,details as below:
The weight of this data is calculated according to the “factory default setting”. The data is the experimental value for reference only. If the difference is subject to actual
conditions.
(
Tolerance
:±
1g
)
F11&F09:
Grounds 1 2 3 4 5
Gram 7g 10g 12g 14g 16g
Coffee(
ml)
The amount of coffee flowing out, unit :ml. setting level:
See the screen numerical on the interface, different beverage with different beverage value limits.
Grinder
Selection: left, right or both 。
F11with one grinder without selection.
Temp. level
Different temperature level, selection: Low ,Medium, High.
High
:
Making coffee the water temperature controls at 93~95
℃;
Medium
:
3
℃
lower than high temperature
;
Low
:
3
℃
lower than medium temperature.
Pre-brewing(
s)
The coffee powder pre-soaking time, unit: S, setting level:1~5.
Test
After changing the data , touch “test”, make one drinks based on the setting data.
Save
After changing data, touch “save” to save all the changes.
Exit
Touch “Exit” back to upper menu.
Technicup Service Manual