Dr.coffee Service Manual 31
8.2 Appointed error
No.
warning
Cause
solution
1
HMI Communication Error
a) The communication line between the main board
and the HMI board is disconnected or damaged.
b) Components damaged
Switch off , 5seconds later reboot the machine
Replace front panel refer to 9.2.7
2
Coffee Thermo-block
Heating Overtime
a) When the heating plate is working, the
temperature change is less than 1 ° C in 3
seconds, the cycle is detected 5 times, and the
above conditions are satisfied each time.
Switch off , 5seconds later reboot the machine
Replace thermos-block grouprefer to 9.2.12
3
Steam Thermo-
block
Heating Overtime
a) When the heating plate is working, the
temperature change is less than 1 ° C in 3
seconds, the cycle is detected 5 times, and the
above conditions are satisfied each time.
Switch off , 5seconds later reboot the machine
Replace thermos-block grouprefer to 9.2.12
4
Coffee Thermo-block NTC
Error
a) The temperature of the thermos-block
exceeds
180 °C
b) Electronic fault between sensor and master
c) Sensor damaged
Switch off,30 minutes later reboot the machine
Replace thermos-block grouprefer to 9.2.12
5
Steam Thermo-block NTC
Error
a) The temperature of the thermos-block
exceeds
180 °C
b) Electronic fault between sensor and master
c) Sensor damaged
Switch off,30 minutes later reboot the machine
Replace thermos-block grouprefer to 9.2.12
6
Thermo-block Water
Supply Error
a) The coffee flow meter does not detect the signal
when it is turned on.
b) No water
c) Pump damaged
d) Water flow system blocked or damaged
e) Brewer blocked
f) Flow meter blocked
g) Power error
Check if the flowmeter cable is disconnected or disconnected
Check if the valve of the external water source is open
Change pumprefer to 9.2.11
Check if the water system is damaged or the position of the manual
switching valve is incorrect.
Check the brewer id blocked
Check the flow meter if blocked refer to 9.2.4
change power PCBrefer to 9.2.10
7
Brewer Error
a) brewer is stuck and blocked
b) brewer damaged
c) brewer motor damaged
Check if there is any foreign matter in the brewer
Switch off , 5seconds later reboot the machine
Disassemble the brewer to check and rinserefer to 9.2.2
Change brewerrefer to 9.2.2
Change motorrefer to 9.2.13
8
Diverted Valve Error
a) The valve is still in the wrong position after
multiple self-tests
b) Valve damaged
Switch off , 5seconds later reboot the machine
Change Valve(refer to 9.2.3
9
Grinder Error
a) Grinder jam or overload protection
b) Motor damaged
c) Electronic parts damaged
d) Hall sensor damaged
Switch off , 5seconds later reboot the machine
Remove the foreign body after removing the grinder
Change grinderrefer to 9.2.6
Change Power PCBrefer to 9.2.10
Change hall sensor refer to 9.2.6