Dr.coffee Service Manual 32
8.3 Without pointed error
No.
error
Cause
solution
1 Boot without display
a) The machine is not unplugged
b) The machine not started
c) Power PCB damaged
Check if the machine is plugged
Check if the machine is started
Replace power PCBrefer to 9.2.10
2 No milk
a) Milk tank empty
b) Milk system blocked
c) Milk frother blocked
d) Milk temperature adjustable button too tight
e) The seal ring is broken, air leakage
Check if the milk container is full filled
Milk system rapid rinse
Disassemble milk frother and clean under water
Rotate the milk temperature adjustment knob counterclockwise
Exchange seal ring
3 No milk foam , milk is fine
a) Air inlet valve locked
b) Air inlet tube blocked
Unblock the air intake or replace
Check inlet tube
4 No coffee
a) Division valve at wrong position
b) Coffee grounds too fine
c) Filter of brewer blocked
d) Brewer water leakage
Reboot machine ,division valve self-clean
Turn the grinding degree to rough position
Wash and clean brewer filter
Disassemble brewer or replace brewer
5 crash a) The system stopped working unexpectedly
Switch off , 5seconds later reboot the machine
Upgrade software
6 Water leakage
a) Division valve water leakage
b) Two-way valve water leakage
c) Check valve in drip tray water leakage
d) water tank water leakage
Change division valve
Change two –way valve
Press the check valve to reset multiple times or replace the check valve
Change water tank
Technicup Service Manual