40 Technical manual | X-am
®
2800 / X-am
®
5800
Maintenance
Procedure:
1. Switch off the gas detector.
2. Loosen the screw and remove the power pack.
NOTICE
Damage to the display
When lifting out the front housing cradle, it can happen (in rare cases) that the
display remains caught in the front housing cradle and becomes damaged as a
result.
Lift out the front housing cradle carefully. If the display gets caught, first carefully
loosen the display from the front cradle and then remove the front housing
cradle entirely.
3. Loosen 4 screws and carefully remove the front housing cradle.
6.13.2 RFID transponder (optional)
The gas detector may also include an RFID transponder. The transponder is
mounted to the lower part of the housing using double-sided adhesive tape.
Prerequisites:
The gas detector is open.
5158651588