50 Technical manual | X-am
®
2800 / X-am
®
5800
Technical data
11.2 Dimensions
1) The minimum permissible ambient temperature is reduced to -20 °C when the gas detector is
equipped with a PID sensor.
2) Tested with power pack HBT 0010 (order no. 3703887)
3) The parameters are complied with when using the battery charger specified by Dräger.
Operating time for X-am 2800 under normal conditions (diffusion mode)
1)
:
1) Nominal operating time of the gas detector at an ambient temperature of 20 to 25 °C,
1013 hPa, less than 1 % alarm time. The actual operating time will vary depending on the
ambient temperature and pressure as well as the rechargeable battery and alarm conditions.
with CatEx and 3 EC sensors Typically 12 h
with 3 EC sensors Typically 100 h
Operating time for X-am 5800 under normal conditions (diffusion mode)
1)
:
1) Nominal operating time of the gas detector at an ambient temperature of 20 to 25 °C,
1013 hPa, less than 1 % alarm time. The actual operating time will vary depending on the
ambient temperature and pressure as well as the rechargeable battery and alarm conditions.
with CatEx and 3 EC sensors Typically 12 h
with XD IR and 3 EC sensors Typically 100 h
with PID and 3 EC sensors typically 24 h
with 3 EC sensors Typically 100 h
51739