7.6. TSIM: Simulating the Input Channels
Deactivated channels (no sensor
connected) are automatically skipped in the
respective menus!
Use potentiometer “L” (by turning the
screw) to simulate a measuring value in
order to check the alarm thresholds and the
configuration.
T S I M
T B
T A
T D
T C
T E
T F
T R E T
A x x x
B x x x
C x x x
D x x x
E x x x
F x x x
F1
F2
Test alarm
thresholds
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F1
Menu selection
Turn "L" left: +
Turn "L" right: -
Turn "L" left: +
Turn "L" right: -
Turn "L" left: +
Turn "L" right: -
Turn "L" left: +
Turn "L" right: -
Turn "L" left: +
Turn "L" right: -
Turn "L" left: +
Turn "L" right: -
Wait until the desired
sensor is displayed and
press and hold F2 to stop
scrolling of the display.
When F2 is released, the
display resumes scrolling

Related product manuals