42
Maintenance
Replacing the Batteries / Rechar-
geable Batteries
Switching off the device:
Keep the key and the key de-
pressed at the same time.
1 Loosen the screw (2.0 mm hexagon sok-
ket) on the power pack and remove the
power pack.
2 Replace the alkaline batteries with new
ones or rechargeable NiMHy batteries
with charged ones – ensure correct po-
larity.
3 Completely replace the power pack T4
(with sealed rechargeable batteries, or-
der no. 83 18 704).
Insert the power pack into the device and
tighten screw, the device is switched on
automatically.
After replacing the power pack T4, it is
recommended that a complete charging is
carried out.
After batteries have been replaced:
The settings and data are stored when
the battery is replaced.
The sensors warm up again.
WARNING
Do not replace the batteries / rechargeable batteries in hazardous areas. Danger of explo-
sion!
Batteries / rechargeable batteries are part of the Ex approval. Only the following types may
be used:
Alkaline batteries – T4 – (not rechargeable!)
Energizer No. E91, Energizer No. EN91 (Industrial), Varta Type 4106 (power one),
Varta Type 4006 (Industrial)
NiMHy rechargeable batteries – T3 – (rechargeable)
GP 180AAHC (1800) max. 40
o
C ambient temperature.
WARNING
Do not throw used batteries into fire or try
to open them by force. Danger of explo-
sion!
Dispose of the batteries in accordance with
local regulations.