20
STEL / TWA exposure alarm
STEL and TWA alarms cannot be acknowledged or cancelled.
Switch off the instrument. The values for the exposure evaluation are deleted after
the instrument is switched on again.
Battery pre-alarm
Acknowledging the pre-alarm:
Press the key. Only the audible alarm and the vibration alarm are switched off.
The battery still lasts approx. 20 minutes after the first battery pre-alarm.
Battery main alarm
The battery main alarm cannot be acknowledged or cancelled:
The instrument is automatically switched off again after 10 seconds.
Before the instrument is switched off, the visual, audible and vibration alarms are
activated for a short time.
Instrument alarm
The instrument or one or several sensor channels are not ready for operation.
For remedies, refer to page 28 to page 35.
If necessary, commission the Dräger Safety Service Center to eliminate the error.
The alarm is indicated by an intermittent alarm message:
Display »A and »« (TWA) or » « (STEL) and measured
value alternating:
WARNING
Risk to health! Leave the area immediately.
After this alarm, the deployment of personnel is subject to the relevant national
regulations.
NOTICE
The STEL alarm can be triggered with a maximum delay of one minute.
The alarm is indicated by an intermittent alarm message:
Flashing special symbol »« on the right side of the display:
The alarm is indicated by an intermittent alarm message:
Flashing special symbol »« on the right side of the display:
The alarm is indicated by an intermittent alarm message:
Special symbol » « on the right side of the display:
OK