8
emit one continuous beep and the bell or siren will sound. If this occurs, you must re-enter
the premises, enter your access code to disarm the system, and then follow the arming
procedure again, making sure to exit the premises in the proper fashion. Your installer will
inform you if the Audible Exit Fault feature has been enabled on your system.
Stay Arming
This feature, if enabled by your installer, will allow you to arm the perimeter zones while
leaving the interior zones inactive so that you can remain on the premises while the system
is armed. When you enter your security code to arm the system and do not exit the premises
through a designated Exit/Entry door, the system will arm in the Stay mode, automatically
bypassing the interior zones.
The interior zones can be reactivated at any time by entering [][1] at any keypad. If you
reactivate the interior zones, be sure to only inhabit areas not covered by motion detectors.
To access areas protected by motion sensors, you must enter your security code and
disarm the system.
Arming Without Entry Delay
If you wish to arm your system without the entry delay, enter [][9] then your access code.
The Armed light will flash as a reminder that the system is armed and has no entry delay. An
entry through any zone programmed as a delay zone will create an instant alarm.
Quick Arm
When the Quick Arm feature is enabled, the system may be armed by simply pressing [][0]
instead of your access code. Please note that pressing [][0] will only allow you to arm the
system; to disarm, you must enter a valid access code. Your installer will inform you if the
Quick Arm feature has been enabled on your system.
Auto Arming
Your system can be programmed to automatically arm itself according to a programmed
schedule. To program the auto arm time, enter [][6] followed by your Master Code. Press
[3]. Enter the time using the 24Hr format (00:00 - 23:59).
To enable or disable the auto arm feature, enter [][6] followed by your Master Code. Press
[2] to either enable or disable the feature. The keypad will beep 3 times if the feature is ON
and once if it is OFF.
NOTE: The correct system time and date must be programmed in order for the auto
arm feature to function properly. Please see “Setting the System Date and Time” on
page 14 for instructions.
Quick Exit
When the Quick Exit feature is enabled, pressing [][0] while the system is armed will
provide a two minute window for you to exit the premises. During this time, you may only
open and close the designated Entry/Exit door once. Once the door is closed, the panel
will end the two minute quick exit delay. If the door is opened again, or if the door is not
closed after two minutes, or if another zone is opened, the panel will begin the entry delay.
Your installer will inform you if the Quick Exit feature has been enabled on your system.
Disarming the System
Disarming from an LED Keypad:
Enter the premises through a designated Exit/Entry door; entering by any other door will
sound an immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep
to indicate that the system should be disarmed. Go to the keypad and enter your access
code. If an error is made entering the code, enter your code again. As soon as the
correct code is entered, the Armed light will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid
access code is not entered during this time, the system will go into alarm. The entry time
delay may be changed by your installer.
If an alarm occurred while the system was armed, the Memory light (or System light for a
PC1555RKZ keypad) and the zone light corresponding to the zone which caused the alarm
will flash for 30 seconds. After the 30 second period, the Memory light (or System light) and
zone light will stop flashing and the panel will return to the Ready state. Pressing the [#] key