2HP14SplitSystemHeatPump
seer
14
2HP14SplitSystemHeatPump
seer
14
Outdoor
Model
Indoor Model
Outdoor Ambient Temperature
Piston or
Field
Factory
Installed
65 60 55 50 47 45 40 35 30 25 20 17 15 10
2HP14*18P
RBCS2M18C
*****P+TXV
RBCS2M18C
*****T
Btuh
21,700 20,600 19,400 18,100 17,300 16,800 15,600 14,400 11,800 10,900 10,100 9,500 9,100 8,200
Kw
1.55 1.52 1.49 1.46 1.45 1.44 1.41 1.38 1.37 1.36 1.33 1.31 1.30 1.27
COP
4.10 3.95 3.80 3.62 3.50 3.42 3.24 3.05 2.49 2.35 2.21 2.12 2.06 1.89
2HP14*24P
RBCS2M24C
*****P+TXV
RBCS2M24C
*****T
Btuh
27,400 25,900 24,400 22,800 21,800 21,100 19,600 18,100 17,700 16,300 15,000 14,200 13,700 12,300
Kw
2.08 2.04 2.00 1.96 1.94 1.92 1.88 1.84 1.83 1.81 1.79 1.78 1.76 1.73
COP
3.85 3.72 3.57 3.41 3.30 3.22 3.06 2.88 2.55 2.41 2.27 2.18 2.12 1.95
2HP14*30P
RBCS2M30C
*****P+TXV
RBCS2M30C
*****T
Btuh
32,700 30,900 29,100 27,200 26,000 25,200 23,400 21,600 21,100 19,700 19,100 18,400 17,700 15,900
Kw
2.40 2.35 2.30 2.25 2.22 2.19 2.14 2.09 2.07 2.01 1.94 1.92 1.87 1.85
COP
3.98 3.85 3.71 3.55 3.44 3.36 3.20 3.02 2.62 2.49 2.35 2.26 2.20 2.03
2HP14*36P
RBCS2M36C
*****P+TXV
RBCS2M36C
*****T
Btuh
41,500 39,300 37,000 34,600 33,000 32,000 29,700 27,400 25,400 23,500 21,600 20,400 19,600 17,600
Kw
3.08 3.01 2.95 2.88 2.84 2.82 2.75 2.69 2.67 2.66 2.59 2.55 2.53 2.46
COP
3.95 3.82 3.67 3.51 340 3.32 3.16 2.98 2.73 2.58 2.44 2.34 2.27 2.10
2HP14*42P
RBCS2M42C
*****P+TXV
RBCS2M42C
*****T
*****P+TXV
Btuh
48,400 45,800 43,100 40,300 38,500 37,300 34,700 32,000 29,700 27,400 25,200 23,800 22,900 20,600
Kw
3.54 3.48 3.42 3.35 3.32 3.29 3.23 3.17 3.15 3.13 3.07 3.03 3.01 2.94
COP
4.00 3.85 3.69 3.52 3.40 3.32 3.14 2.95 2.71 2.56 2.40 2.30 2.23 2.05
2HP14*48P
RBCS2M60C
*****P+TXV
RBCS2M60C
*****T
Btuh
57,200 54,100 51,000 47,600 45,500 44,100 41,000 37,800 34,100 31,500 29,000 27,400 26,400 23,700
Kw
3.98 3.90 3.83 3.75 3.70 3.67 3.60 3.52 3.44 3.36 3.28 3.24 3.21 3.13
COP
4.20 4.06 3.90 3.72 3.60 3.52 3.33 3.14 2.91 2.75 2.59 2.48 2.41 2.21
2HP14*60P
RBCS2M60V
*****P+TXV
---
Btuh
66,000 62,500 58,800 55,000 52,500 50,900 47,300 43,600 39,900 36,800 33,900 32,000 30,800 27,600
Kw
5.04 4.93 4.83 4.72 4.66 4.62 4.52 4.41 4.35 4.24 4.14 4.08 4.03 3.93
COP
3.83 3.71 3.56 3.41 3.30 3.23 3.06 2.89 2.68 2.54 2.40 2.30 2.24 2.06
HeatingPerformancewithExtendedRatings
* = B, L