Service Manual for Electric Convection Oven
12
ZZ CONTROL PANEL ASSEMBLY
WARNING: DISCONNECT OVEN FROM POWER
SOURCE BEFORE PERFORMING
ANY SERVICE.
Component Access Procedure
Remove screw at top center of ZZ Control Panel
assembly and slide Control Panel assembly out to
allow access to Control Panel components.
Temperature
Probe
Screw
ZZ
Control
Panel
Relay
Board
Transformer
208/240V
WARNING
POWER
Oven
Control
Power
Switch
Fuse Holder &
Fuse (10 amp delay)
POWER Switch
1. Perform Component Access Procedure.
2. Tag and disconnect wires from POWER Switch.
3. Disengage POWER Switch from retainer and
remove through front of Control Panel.
4. Reverse procedure to install a new POWER Switch.
ZZ Oven Control
1. Perform Component Access Procedure.
2. Tag and disconnect wires from ZZ Oven Control.
3. Remove two screws securing ZZ Oven Control to
Control Panel and remove Oven Control.
4. Reverse procedure to install a new ZZ Oven Control.
Fuse and Fuse Holder Light
1. Remove Fuse Holder Cap to replace Fuse.
2. Perform Component Access Procedure.
3. Tag and disconnect wires to Fuse Holder.
4. Remove nut securing Fuse Holder.
5. Remove Fuse Holder from front of Control Panel.
6. Reverse procedure to install a new Fuse Holder.