15
Service Manual for Electric Convection Oven
CONTROL CIRCUIT BOARD REPLACEMENT
WARNING: DISCONNECT OVEN FROM POWER
SOURCE BEFORE PERFORMING
ANY SERVICE.
The Control Circuit Board is used only in 5/9
convection ovens used by Popeye’s Chicken or
Churches Chicken.
1. Remove screw at top center of Control Panel
assembly and slide Control Panel out to allow
access to the Control Circuit Board.
2. Remove the two and four wire connectors from
the Control Circuit Board.
3. Remove the Probe connector from the Control
Circuit Board.
4. Remove the defective Control Circuit Board.
5. Install the replacement Control Circuit Board.
6. Attach the two and four wire connectors.
7. Attach the Probe connector.
8. Mount the Relay to the Control Panel below the
Control Circuit Board. DO NOT MOUNT THE
RELAY ON THE CONTROL CIRCUIT BOARD.
CONTROL
CIRCUIT
BOARD
PROBE
TRANS.
RELAY
COM
Blue Wire (Existing)
Purple Wire
(Existing)
Wire Nut
#2 White Wire (New)
#1 Blue Wire
(New)
#32 Black Wire
(Exisiting)
#3 Black Wire (New)
NO NC
9. Attach the new wires #1, #2 and # 3 to the relay,
refer to the gure above for details.
10. Remove the wire nut that secures the 3 black
and 1 purple wire, separate the purple wire from
the bundle.
11. Referring to the gure above connect the #3 black
wire from the relay to the bundle black wires that
contained the purple wire removed in the previous
step and reattach the wire nut.
12. Referring to the gure above connect the purple
wire removed in step 10 to the blue wire and attach
a wire nut.
13. Referring to the gure above disconnect the #32
black wire from the blue wire.
14. Connect the #32 black wire to the common terminal
on the relay.
15. Connect the #2 white wire to the blue wire coming
from the relay and attach a wire nut.
16. Close the Control Panel and reattach its mounting
screw.
17. Proceed to the Control Circuit Board Jumper Setting
Instructions.
CONTROL CIRCUIT BOARD JUMPER
SETTINGS
The Control Circuit Board is shipped with the jumper
in position 3. Position 1 loads Churches Chicken’s
default settings. Position 2 loads Popeye’s Chicken’s
default settings.
Single Menu Jumper Setting
(Churches or Popeye’s)
1. Turn the power off to the unit.
2. Remove screw at top center of Control Panel
assembly and slide Control Panel out to allow
access to the Control Circuit Board.
3. Place the jumper in the #3 position, see the diagram
below.