19
Service Manual for Electric Convection Oven
RTD PROBE
WARNING: DISCONNECT OVEN FROM POWER
SOURCE BEFORE PERFORMING
ANY SERVICE.
The RTD Probe is located parallel to the oven door
at the front of the oven cavity for the following ovens:
5/9 The Oven
X Controller
XX Controller
Z and ZX Controller
ZZ Controller
The RTD Probe is located at the top center of the right
wall for the following ovens:
6/13 The Oven
X Controller
XX Controller
Z and ZX Controller
The RTD Probe is mounted on the top right center
wall for the following ovens:
59-E3C and 59-E3P ovens
CCSI Controller
1. Remove screw at top center of Control Panel
assembly and slide Control Panel out to allow
access to the RTD Probe connection on the Relay
Board.
2. Disconnect RTD Probe connector from Control
Board.
To RTD probe
in oven
Typical
board connection
3. Remove RTD Probe from inside of the oven and
pull connector through side of oven to remove.
4. Reverse procedure to install a new RTD Probe.
THERMOSTAT
WARNING: DISCONNECT OVEN FROM POWER
SOURCE BEFORE PERFORMING
ANY SERVICE.
The Thermostat is located on the V Controller and
the Thermostat Probe is located in the upper right of
oven. The Thermostat Probe provides temperature
information back to the Thermostat. The capillary tube
from the Thermostat to the Thermostat Probe is covered
with a berglass sleeve.
NOTE: When removing the Thermostat be careful not
to bend the capillary tube at a sharp angle to
prevent kinking.
1. Remove screw at top center of Control Panel
assembly and slide Control Panel out to allow
access to the Thermostat Probe capillary tube.
2. Open Oven Door and carefully remove Thermostat
Probe from bracket at upper right side of the oven.
2. Pull Thermostat Probe through the oven sidewall.
3. Remove Thermostat knob from front of V Controller
assembly.
4. Tag and disconnect wires from back of Thermostat.
5. Remove nut securing the Thermostat to front of V
Controller assembly.
6. Pull Thermostat off rear of V Controller assembly.
7. Reverse procedure to install a new Thermostat.
Be sure berglass insulation is on capillary tube
to Thermostat Probe.