andcoldimpactto-40degreeF(-40degreeC).
3. CSAcertied–PlasticTypeBroofvents,forinstallation
on sloping surfaces.
4. MiamiDadeHighVelocityHurricaneZonecertied.
5. Model:Black(60PRO50SLBL)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
6. Model:Brown(60PRO50SLBR)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
7. Model:White(60PRO50SLW)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
8. Model:Grey(60PRO50SLG)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
9. Model:Weatherwood(60PRO50SLWW)18inchesx
24inchesx3-1/2inches(457mmx610mmx89mm).
D. Product: 3 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
130sq.in.(838sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO150BL)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
5. Model:Brown(60PRO150BR)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
6. Model:Gray(60PRO150G)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
7. Model:Weatherwood(60PRO150WW)21-1/8inches
x21-1/8inchesx22inches(536mmx536mm
x559mm).
E. Product: 2 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
95sq.in.(613sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO140BL)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
5. Model:Brown(60PRO140BR)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
6. Model:Grey(60PRO140G)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
7. Model:Weatherwood(60PRO140WW)21-1/8inches
x21-1/8inchesx19-1/2inches(536mmx536mm
x495mm).
F. Product: 1 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
48sq.in.(310sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO130BL)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
5. Model:Brown(60PRO130BR)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
6. Model:Grey(60PRO130G)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
7. Model:Weatherwood(60PRO130WW)21-1/8inches
x21-1/8inchesx17inches(536mmx536mm
x432mm).
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been
properly prepared.
B. If substrate preparation is the responsibility of another
installer, notify Architect of unsatisfactory preparation
before proceeding.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by
the manufacturer for achieving the best result for the
substrate under the project conditions.
3.3 INSTALLATION
A. Install in accordance with manufacturer’s instructions
and in proper relationship with adjacent construction.
3.4 FIELD QUALITY CONTROL
A. ProvideinspectioncerticatesofAuthorityHaving
Jurisdiction(AHJ).
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before
substantial completion.
END OF SECTION