4
MAINTENANCE
SPECIFICATIONS
Changing the battery
To install or change the AAA batteries, open the battery compartment. Replace only
with the same type of battery observing the correct polarity.
Cleaning the lens
Blow off loose particles using clean compressed air. Carefully wipe the surface with a
moist cotton swab. The swab may be moistened with water.
Cleaning the casing
Wipe using a damp cloth or sponge. Do not use solvents as these may damage the
casing. Do not immerse in water.
Measurement Range -50
o
to 330
o
C (-58
o
to 626
o
F)
Resolution 0.1
o
C/F
Accuracy 0
o
C~330
o
C (32
o
F~626
o
F): ± 1.5
o
C (± 2.7
o
C) or
± 1.5% -50
o
C~0
o
C (-58
o
F~32
o
F): ± 3
o
C (± 5
o
F)
Whichever is greater
Repeatability ±1% of reading or ±1
o
C
Response time (95%) 500ms, 95% response
Distance to spot 12:1
Emissivity 0.95 preset
Laser
Sighting Single point laser
Power Class 1 Output <1mW, wavelength 630 to 670mm
Power Supply 2x 1.5V AAA Battery
Battery Life Laser off: 12hrs
Weight 69g
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT
These symbols indicate that separate collection of Waste Electrical and Electronic Equipment
(WEEE) or waste batteries is required. Do not dispose of these items with general household
waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries
can be returned to any waste battery recycling point which are provided by most battery retailers.
Contact your local authority for details of the battery and WEEE recycling schemes available in
your area.
Made in China. PR2 9PP
Man Rev 1.0