2.10.2 Height of the lifted sewing feet and lift limitation
Caution: Danger of injury !
Switch off main switch.
Check and adjust height of the lifted sewing feet only when the sewing
machine is switched off.
Standard checking
The distance between the lifted sewing feet and the throat plate should
amount to 20 mm.
Turn handwheel until both sewing feet rest on the throat plate.
Lift the sewing feet and measure the lifting height.
Correction
Loosen screw 1.
Adjust the dowel pin 2 correspondingly.
Dowel pin to the left = Sewing feet lower
Dowel pin to the right = Sewing feet higher
Tighten screw 1.
Check adjustment and correct, if necessary.
ATTENTION: Danger of breakage !
When the sewing feet are lifted, there must be a distance of at least 0.2
mm between the presser foot and the fabric bar bush.