Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016 167
.. .. 22 Magnet wheel search
timeout
Check connection cables
Check stepper motor for stiff
mo
vement
.. .. 30 Stepper motor not
re
sponding
Perform software update
Replace the control
.. .. 41 Stepper motor not
re
sponding
Stepper motor card
defective
Perform software update
Replace stepper motor card
.. .. 52 Stepper motor
over
current
Stepper motor defective
Control defective
Replace the stepper motor
Replace the control
.. .. 53 Stepper motor
over
voltage
Line voltage too high Check the line voltage
.. .. 55 Stepper motor
over
load
Stepper motor not moving
freely or blocked
Stepper motor defective
Control defective
Eliminate sluggishness/
blockage
Replace the stepper motor
Replace the control
.. .. 56 Stepper motor
over
temperature
Stepper motor not moving
freely
Stepper motor defective
Control defective
Eliminate sluggishness
Replace the stepper motor
Replace the control
.. .. 62 Stepper motor IDMA
aut
o-increment
•Disturbance Switch the machine off and
on again
3100
3103
Machine: Voltage fault Temporary line voltage
in
terruption
Check line voltage and
stabilize, if required
3221
3222
Machine: Thread
ten
sion regulation
Internal error Switch the machine off and
on again
Perform software update
Contact Customer Service
Error Meaning Possible cause Remedial action