Troubleshooting
Operating Instructions 581 - 01.0 - 05/2016 167
.. .. 22 Magnet wheel search
timeout
• Check connection cables
• Check stepper motor for stiff
mo
vement
.. .. 30 Stepper motor not
re
sponding
• Perform software update
• Replace the control
.. .. 41 Stepper motor not
re
sponding
• Stepper motor card
defective
• Perform software update
• Replace stepper motor card
.. .. 52 Stepper motor
over
current
• Stepper motor defective
• Control defective
• Replace the stepper motor
• Replace the control
.. .. 53 Stepper motor
over
voltage
• Line voltage too high • Check the line voltage
.. .. 55 Stepper motor
over
load
• Stepper motor not moving
freely or blocked
• Stepper motor defective
• Control defective
• Eliminate sluggishness/
blockage
• Replace the stepper motor
• Replace the control
.. .. 56 Stepper motor
over
temperature
• Stepper motor not moving
freely
• Stepper motor defective
• Control defective
• Eliminate sluggishness
• Replace the stepper motor
• Replace the control
.. .. 62 Stepper motor IDMA
aut
o-increment
•Disturbance • Switch the machine off and
on again
3100
–
3103
Machine: Voltage fault • Temporary line voltage
in
terruption
• Check line voltage and
stabilize, if required
3221
–
3222
Machine: Thread
ten
sion regulation
• Internal error • Switch the machine off and
on again
• Perform software update
• Contact Customer Service
Error Meaning Possible cause Remedial action