NO.
CONT.ON 32 PAGE NO.31
Copyright (C) 20
20
Dynabook Inc., All Right
s
Reserved.
The detail of the error will be recorded to the WPETD log file as below.
Message Explanation Remarks
File Access Error. xx:. Failed in accessing the file.
XX is the SD storage card drive letter.
Space Size Error. xx: There is no free space for creating the file.
XX is the SD storage card drive letter.
4) Test file
WinPETD.exe: Test program.
4-2-5 ODD Test
1) Test contents
This test reads the data file in an optical medium (*1) in the drive (External drive is also available) to check if it reads the data
correctly. The test reads 64MB data from the file.
Note (*1):
As explained in 2-2ts, you have to prepare an optical medium including the test data file CDDTEST0.DAT in the root
folder.
2) Test screen
3) Result judgment
In case of PASS
OK is shown in theResult” field on the Diagnostics dialog.
The pass count is shown in the PASS field.
In case of FAIL
NG is shown in the Result” field on the Diagnostics dialog.
The pass and error count are shown in the PASS and ERROR fields respectively.
4-2-6 WIRED LAN Test
1) Test content
This test checks if the data is sent and received without timeout between the built-in LAN device and DHCP server. The 32-packet
sized data is sent from the PC and will confirm to get the response from the server.
The check is executed 5 times for 1 Pass.
Note that, it is necessary that the IP Address has to be assigned to the Wired LAN adapter by a DHCP server for executing the test.
If you use an attached Wired LAN adapter such as a USB LAN adapter, remove it from the PC as WPETD cannot detect the built-in
adapter correctly.
2) Test Screen

Table of Contents

Other manuals for dynabook SATELLITE PRO C50-H

Related product manuals