2 Troubleshooting 2.10 Audio
2-18 SatellitePro L50-G / dynabookP*-C* MaintenanceManual
2.10 Audio Test
Procedure1 Windows Application Test
Procedure 2 Connector Check and Replacement Check
Procedure 1 Windows Application Test
Procedure 2 Connector Check and Replacement Check
Check1 Make sure the Speakercable hasbeen firmly connected to the systemboard.
If the cableislooseor off, reconnectit firmly and return to Procedure1. If
there isstill an error, perform Check2.
Check2 The Speakermay be faulty. Replaceit with a new one following the
instructions in Chapter 4. If the problem persists,perform Check3.
Check3 The Systemboard maybe faulty. Replaceit with a new one following the
instructionsin Chapter4. If the Audioisstill not functioning properly,
perform Check4.
Check4 The memory maybe defective. Replacethe memory module with a new one
following the stepsdescribedin Chapter 4.