09
10 Push the water pipe as far as possible onto the new Solenoid.
11 Clip the solenoid into the Backplate.
12 Connect the Solenoid to the Solenoid to PCB loom.
13 Locate the water pipe clip onto the end of the water pipe and fasten into place.
Fit the two Phillips screws.
14 Attach the mains water supply to the Solenoid.
15 Turn on the mains water supply. Check that there are no leaks at the Solenoid inlet.
Turn on the power to the product. Insert hands under the centre of the tap to activate the water.
Check that there are no leaks at the Solenoid outlet.
16 Refit the water cover and two screws.
17 Hook the top of the Motorbucket into the backplate. Push the bottom of the Motorbucket into
position in the backplate.
If previously fitted, fit the T-15 screw into the Motorbucket release catch.
18 Clip the HEPA filter assembly into the base of the Motorbucket.
After reassembling the product follow the instructions on page 2 to test the product for adequate
operation.
Section 1
Solenoid assembly fitting