20
01 Carefully release the grommet holding the Comms to PCB loom assembly.
02 Carefully release the grommet holding the Solenoid to PCB loom assembly.
03 Undo the Cable gland cap.
04. Remove the mains supply cord from the Backplate assembly.
05. Remove all screws attaching the Backplate Assy to the wall.
Backplate replacement fitting
01 Attach the new Backplate assembly to the wall.
02. Remove the Cable gland cap from the new Backplate assembly and slide over the mains power
supply cord.
03. Locate the mains power supply cord through the cable gland (it may be necessary to ‘open up‘
the Gland to ease entry).
04. Tighten the Cable gland cap.
05. Refit both loom assemblies ensuring that both grommets are completely sealed.
Important: if either grommet is damaged to the extent that you are not satisfied that it continues
to offer a watertight seal, a new loom must be fitted.
After fitting both looms, the following parts should be fitted as previously shown:
Power supply assembly (page 14),
Air hose assembly (pages 15 & 16),
Solenoid assembly (pages 7-8).
After reassembling the product follow the instructions on page 2 to test the product for adequate
operation.
Section 3
Backplate replacement removal
Warning: before continuing ensure the power and water supplies to the the machine are switched off.
Before continuing the following parts need to be removed as previously shown:
the Solenoid assembly (pages 5-6), and the Air Hose and Power supply assemblies (pages 10-13).