Note: it is advisable to remove the Tap from it’s location prior to fitting the internal components.
01 Remove the nut from the Tap stem.
Remove the Tap.
02 Feed the Comms cable through the Water pipe assembly housing.
03 Locate the Comms cable into the Water pipe assembly housing ensuring the outer insulation is
securely fitted in all three grip details.
04 Feed the Comms cable and Water pipe assembly through the front of the tap.
05 Wrap the Thermal insulating sleeve around the Water pipe housing.
Note: the central hole in the sleeve locates over the Aerator housing.
06 Slide the Thermal insulating sleeve and components carefully into the stem.
07 Ensure the Water pipe assembly housing sits squarely within the Tap, and is aligned with the
Aerator hole. Using the Aerator tool screw the Aerator into the housing hand tight.
08 Crease the Lens housing assembly at the split line and slide it into the Tap.
09 Ensure all individual lenses are seated centrally and are flush with the details in the underside of
the tap.
10 Carefully feed the Comms cable connector through the PCB housing inner. Slide the PCB housing
inner fully into the Tap.
11 Fit the T-8 screw.
12 Carefully connect the Comms cable to the PCB assembly.
13 Carefully locate the PCB assembly into the PCB housing inner. Ensure the PCB sits behind the two
clips.
Important: the PCB must be seated squarely. Failure to do so may result in the continuous flow of
air or water.
14 Ensure the surface of the PCB housing outer is clear of any glue residue. Locate the PCB housing
outer ensuring it clips into position.
15 Inspect the EPDM (black) and Gel (blue) seals attached to the Glamour cap. If either appear to be
damaged replace them. If you replace the Gel seal, it will be necessary to remove the plastic film
from it before fitting the Glamour cap.
16 Locate the Glamour cap into the Tap. Retighten the grub screw until the Stem cap is fully secured
(approximately 12-15 turns).
17 After fitting the Glamour cap you should continue by following the instructions in the ‘Air hose/Tap
assembly fitting’ section of this manual (page 15).
Note: if you have replaced the Water pipe service assembly, it will be necesary to cut the pipe at
the dotted line prior to attaching it to the Solenoid assembly.
After reassembling the product follow the instructions on page 2 to test the product for adequate
operation.
Section 4
Internals of Tap replacement fitting
29