Emax II operation manual
151
DYNAMIC PROCESSING 11 VOICE ATTENUATION,
TUNING, and DELAY
This function varies the attenuation, tuning, and delay for the current voice.
1. Activate DYNAMIC PROCESSING 11. The display will say:
Attn Tune Delay
00dB +00ct 00
2. Select the desired parameter for adjustment with the cursor (left arrow/right arrow)
buttons, then vary the parameter as needed:
■ Attn: Use the data slider to attenuate the voice up to 46 dB.
■ Tune: Use the data slider to tune the voice pitch between +45 and -48 cents.
■ Delay: Use the data slider to vary the delay between the time a key is first pressed (or
MIDI data received at the MIDI input) to the onset of the note. The range is 0
to 63.
3. After making your selections, press ENTER to return to the module identifier.
DYNAMIC PROCESSING 12 VCA ENVELOPE
This function sets the attack, hold, decay, sustain, and release characteristics of
the VCA’s AHDSR envelope generator.
Application: Change a voice’s dynamics with respect to time.
1. Activate DYNAMIC PROCESSING 12. The display will say:
A: A H D S R
XX XX XX XX XX
...where XX is a two-digit numeral between 01 and 32.
Hint: Filter and VCA settings interact. For example, if the VCA is set for an extremely
short decay and sustain level is near 0, then you won’t hear the effects of setting a long
filter decay.
DYNAMIC PROCESSING
Atten, Tuning, Delay
■
Alternate keyboard
tunings may be ob-
tained by defining each
key as a voice and ad-
justing the voice tuning
for each key.