L Switch panel
:
EMERG FUEL VALVE switches
Circuit breakers
All switches
COMM/NAV equipment
Guarded
As required
–Off
–Off
L Overhead panel
:
Power levers
All switches
Circuit breakers
OFF
–Off
As required
L Collective lever panel:
All switches
–Off
Pre-start Check
L Battery switch
–On
For EPU starts:
Battery switch Off
EPU Connected
EPU ON caution light On
L Voltmeter indication :
Battery
EPU
Minimum 24V
Between 24-28V
L Warning/caution lights
Test; all warning and caution lights (ex-
cept both engine Fire, MM indicator LIM-
IT and LOW FUEL warning lights) must
come on
L Both engine Fire warning lights
Test
L Mast moment indicator
Test
L LOW FUEL TEST pushbutton
Press; LOW FUEL warning light must
come on
L Fuel quantity indicator
Check readings
L Fuel pumps (4)
Check function
L Cyclic stick lock (if fitted)
Stowed
L Collective lever lock
Release
L Flight controls
Check for freedom of movement, full
travel