EUROCOPTER
FLIGHT MANUAL BO 105 CB-5/CBS-5
4 - 9
LBA APPROVED
Rev. 0
L Switch panel
:
EMERG FUEL VALVE switches
Circuit breakers
All switches
COMM/NAV equipment
– Guarded
– As required
–Off
–Off
L Overhead panel
:
Power levers
All switches
Circuit breakers
– OFF
–Off
– As required
L Collective lever panel:
All switches
–Off
Pre-start Check
L Battery switch
–On
For EPU starts:
Battery switch – Off
EPU – Connected
EPU ON caution light – On
L Voltmeter indication :
Battery
EPU
– Minimum 24V
– Between 24-28V
L Warning/caution lights
– Test; all warning and caution lights (ex-
cept both engine Fire, MM indicator LIM-
IT and LOW FUEL warning lights) must
come on
L Both engine Fire warning lights
– Test
L Mast moment indicator
– Test
L LOW FUEL TEST pushbutton
– Press; LOW FUEL warning light must
come on
L Fuel quantity indicator
– Check readings
L Fuel pumps (4)
– Check function
L Cyclic stick lock (if fitted)
– Stowed
L Collective lever lock
– Release
L Flight controls
– Check for freedom of movement, full
travel