FLIGHT MANUAL BO 105 CB-5/CBS-5
EUROCOPTER
2 - 8
LBA APPROVED
Rev. 0
2.11 ROTOR RPM LIMITATIONS
EFFECTIVITY Model C Variants
Power ON Power OFF
Minimum Transient 95% —
Minimum Continuous 98% 85%
Maximum Continuous 102% 110%
Maximum Transient (15-sec limited) 105% —
EFFECTIVITY Model S Variants
Power ON Power OFF
Minimum Transient 95% —
Minimum Continuous 98% 85%
Maximum Continuous 102% 104%
Maximum Transient (15-sec limited) 105% 110%
EFFECTIVITY ALL