FLIGHT MANUAL BO 105 CB-5/CBS-5
3 - 7
LBA APPROVED
Rev. 0
WARNING LIGHT INDICATIONS
GEN 1 GEN 2
or
Conditions/Indications
Generator failure
Voltmeter indication normal (27 - 29 V)
GEN warning light (affected generator) on
Generator overvoltage
Voltmeter indication above normal (30 V or more)
GEN warning light (normal generator) on
NOTE Normal generator is disconnected by reverse current of affected generator.
Procedure
NOTE One generator alone will provide sufficient power for normal services. Non-essen-
tial Auxiliary Bus loads are shed automatically.
D G E N E R A T O R F A I L U R E
1. Generator field sw (affected generator) GEN TRIP, then hold in GEN RES for
approx 2 sec and release
If GEN warning light remains on:
2. Generator field sw (affected gener-
ator)
GEN TRIP
3. STARTER/GENERATOR sw (af-
fected generator)
–Off
4. CURRENT IND sw Select normal generator
5. Ammeter and voltmeter Monitor
D G E N E R A T O R O V E R V O L T A G E
1. Generator field sw (affected generator) GEN TRIP
2. STARTER/GENERATOR sw (affected
generator)
–Off
3. GEN warning light (affected generator) Check on
4. GEN warning light (normal generator) Check off
5. CURRENT IND sw Select normal generator
6. Ammeter and voltmeter Monitor