WARNING LIGHT INDICATIONS
LOW
FUEL
Conditions/Indications
Failure of both main tank pumps, or
Main tank empty
Supply tank fuel quantity below 60 kg (75 l)
Procedure
1. Supply tank fuel level Check
2. Main tank fuel level Check
3. Both fuel main pump circuit breakers Check in
4. Both fuel main pump switches Check on
If LOW FUEL warning light remains on:
5. LAND WITHIN 10 MINUTES