EW-ECO SERIES OPERATION MANUAL
Length of line, there is less
than or equal to the set
length
1、the wire itself line thickness a.
2、a rolling wheel with dirt, required to be cleaned. The conductor surface
wax, lead into, wire wheels slip with sticky wax, wire brush, and gasoline
cleaning four rolling wheel.
3、take out wire, level “ 00 ” air operation phenomenon, be excluded.
4、the wire laying frame having card hysteresis phenomenon, leading to poor
conveying wire.
Head and tail cut or no cut
1、check the head or tail of sevred, wire diameter is too small, should adjust
the “ wire ” bigger. ( a reference value 30-90 )
2、Checking thread tail no cut marks, wire diameter is too lare, should adjust
the “ wire ” smaller. ( a reference value 30-90 )
Sometimes the head or tail
was cut off
1 、 wire wheel, the pressure is not enough, please check and regulation of
“ round round pressure regulating knob ”, make the pulley pressure
becomes great.
2 、 the line wheel clearance is too large, need to adjust the “ into the line
wheel clearance adjustment knob ”, the line wheel clearance reduction.
There are several strands of
wire long thread
1 、 wire diameter is too small, the cut wire, strip with a copper wire, to
increase the diameter of 1-2, try again.
2、retreat knife set too small, it should be increased the retracting parameters
(00-10 )
Sometimes the conducting
wires together no knife
broken
1、the edge parts activities with the ordinary oil, try again (usually 8 hours
filling a ).
2、the speed is slow.
3、check the wire specifications in AWG12# line ( 3 square ).
4、the blade is blunt, flat grinding, or replacement.
5、according to the seventh part of the third inspection.
Press run after shutdown can
only cut a, screen appears
“ short line or knot ”
1、no line of automatic shutdown function, belongs to the normal.
2 、 setting the length should be greater than 32 mm ( except for the 98
procedures ).
3、wire wheel clearance is too large, is required for the regulation of “ round
round gap adjustment knob ” make the pulley reduced gap.
When the power is switched
on the fan to work normally,
screen normal, but according
to “ run ” after the machine
can not move
1、because of the voltage instability or illegal operation of the circuit board in
the insurance pipe burn, need to replace the fuse ( open the case cover,
visible in the circuit board has two 5A insurance tube ).
2、such as changing insurance tube, continue to burn out, and my company
customer service service department or office contact.
Incision inclined tangent
1、wire itself is too curved, the purchase of a straightening device.
2、a lead mouth without facing edge center.
3、a tail tilts, inspect the wire pipe is leaning against the tool too close.