QST-30/60
SCROLL COMPRESSOR
INS TRUCTIONS
Item #31700

Questions and Answers:

Eastwood QST-30/60 Specifications

General IconGeneral
Power SourceElectric
Maximum Pressure175 PSI
TypeStationary
Horsepower3 HP
Max Pressure175 PSI
Voltage230V
PhaseSingle Phase
Pump RPM1075 RPM
Noise Level78 dBA

Summary

Specifications

Safety Information

Read Instructions

Thoroughly read and understand product instructions before using the compressor. Keep for reference.

Fire or Explosion Hazard

Never spray flammable liquids in confined areas. Operate in well-ventilated area, do not smoke while spraying.

Fire Hazard

Never allow compressor to operate unattended. Always switch to 'OFF' before leaving work area.

Electrical Shock Hazard

Never use outdoors in rain or on wet surface. Must be installed by licensed electrician.

Injury Hazard

Unit starts automatically. Shut off power, bleed pressure before servicing. Do not run with cover removed.

Burn Hazard

Scroll Pump generates heat during operation. Use caution when servicing to avoid burns.

Eye Injury Hazard

Always wear ANSI Z87 approved eye protection. Air, moisture, debris can be ejected at high velocity.

Health Hazard

Air discharged is not for human consumption. Never use as supply air for human consumption.

Burst Hazard

Regulate outlet pressure to tool's max rating. Relieve pressure before attaching/removing accessories. Do not weld/drill tank.

General Caution

Drain moisture daily. Ensure 12 inches clearance for ventilation. Do not block cover ventilation holes.

Compressor Set-Up

Check Oil Level

Oil is critical for operation. Check level before other steps. Follow safety precautions for pressure release.

Check Air Filter

Remove lid, check paper element is in place, and re-install lid. Ensure snorkel points downward.

Electrical Connection

Wiring by licensed electrician. Dedicated circuit with breaker/fuse. Adequately sized supply wiring is crucial.

Check Run Procedure

Perform run check before use. Close outlet valves, connect power, move switch to ON, listen for leaks.

Compressor Location

Positioning

Provide space for cooling. Locate intake grill 1ft from wall. Maintain 2ft overhead clearance. Do not block vents.

Caster Locking

Compressor vibrates and moves. Always lock casters before running. Push down paddles to lock brakes.

Air Line Connection

Compressor Operation

Condensation Drain

Maintenance

Oil Change

Perform after 1st year. Before servicing, allow unit to cool. Follow safety precautions for pressure release and hot components.

Oil, Filter, and Separator Change

Perform after 3 years. Follow safety guidelines. Drain oil, replace oil filter and moisture separator.

Air Filter Change

Remove filter lid, replace element, and re-install lid. Ensure correct orientation of snorkel and lid.

Troubleshooting

Runs Constantly

Cause: Air demand exceeds capacity. Correction: Reduce air demand or stop use.

Does Not Run

Cause: No power. Correction: Check power source. Call tech if power is present.

Motor Overheating

Cause: High air demand or dirty cooling areas. Correction: Reduce demand, clean grille and heat exchanger.