2 Eaton 9355 UPS (20/30kVA) Installation and Operation Manual 164201626—Rev F www.eaton.com/powerquality
Providing outstanding performance and reliability, the Eaton 9355 UPS's unique benefits including the
following:
l
Online UPS design with pure sine wave output. The UPS filters and regulates incoming AC power and
provides consistent power to your equipment without draining the battery.
l
More wattage in less space with a 0.9 power factor – protecting more equipment and leaving more room for
expansion.
l
A UPS maintenance bypass switch (MBS) that provides a Make-Before-Break (MBB) wrap-around bypass for
UPS maintenance or service without shutting down the load.
l
Support for Powerware Hot Sync
®
paralleling of multiple modules for redundancy or extra capacity.
l
Input current total harmonic distortion (THD) of less than five percent, using active input power factor
correction.
l
ABM
®
technology that uses advanced battery management to increase battery service life, optimize
recharge time, and provide a warning before the end of useful battery life.
l
Over two hours of extended runtime with added EBCs.
l
Advanced power management with the Software Suite CD for graceful shutdowns and power monitoring.
l
Emergency shutdown control through the remote emergency power-off (REPO) port.
l
Start-on-battery capability for powering up the UPS even if utility power is not available.
l
Standard communication options with a DB-9 serial port, relay output contacts, and programmable signal
inputs.
l
Optional X-Slot
®
cards with enhanced communication capabilities for increased power protection and
control.
The following options for the Eaton 9355 are available:
l
Extended Battery Cabinet
Optional EBCs are available with 2 strings or 4 strings, providing up to 2.7 hours of extended runtime.
l
Options Cabinet
The Options Cabinet is available in five models:
l
Options Cabinet with a maintenance bypass switch that provides wrap-around bypass for UPS
maintenance or service without shutting down the load
l
Options Cabinet with both MBS and input isolation transformer that allows operation from a 208V, 480V,
or 600V 60-Hz source (input transformer in single-feed systems or bypass transformer in dual-feed
systems)
l
Options Cabinet for dual-feed systems that provides the second input from a 208V, 480V, or 600V 60-Hz
source
l
Options Cabinet with an output isolation transformer for 480V loads
l
Options Cabinet for single-feed system with MBS, 480V input isolation transformer, and 480V output
transformer.
l
Wall-Mounted Bypass Switch
The optional wall-mounted bypass switch is used to bypass the UPS during maintenance or servicing,
providing wrap-around bypass for UPS service without shutting down the load.