UPS Installation Plan and Unpacking
Eaton 93PM UPS (20–100 kW, 480V – 100 kW Frame) Installation and Operation Manual P-164000227—Rev 6 www.eaton.com/powerquality 3-13
Figure 3-8. Remote EPO Switch Dimensions
Weight and Center of Gravity with Left-Mounted Sidecar (letters A, B, and C map to Figure 3-7)
Frame
A
mm (in)
B
mm (in)
C
mm (in)
Weight
kg (lb)
Eaton 93PM-100-1 UPS with UPS Top Entry Wiring Sidecar (no breakers)
Capacity 844 (33.2) 542 (21.3) 409 (16.1) 406 (894)
Redundant 847 (33.3) 542 (21.3) 410 (16.1) 411 (907)
Eaton 93PM-100-2 UPS with UPS Top Entry Wiring Sidecar (no breakers)
Capacity 911 (35.8) 541 (21.3) 419 (16.5) 469 (1034)
Redundant 913 (35.9) 541 (21.3) 420 (16.5) 475 (1047)
Eaton 93PM-100-3 UPS with UPS Top Entry Wiring Sidecar (no breakers) Redundant 1001 (39.4) 541 (21.3) 427 (16.8) 539 (1188)
Eaton 93PM-100-1 UPS with four breaker SIAC-B
Capacity 855 (33.7) 568 (22.4) 390 (15.4) 433 (954)
Redundant 858 (33.8) 568 (22.4) 391 (15.4) 439 (967)
Eaton 93PM-100-2 UPS with four breaker SIAC-B Capacity 917 (36.1) 564 (22.2) 402 (15.8) 496 (1094)
Redundant 918 (36.1) 564 (22.2) 403 (15.9) 502 (1107)
Eaton 93PM-100-3 with four breaker SIAC-B Redundant 1001 (39.4) 561 (22.1) 412 (16.2) 566 (1248)
Weight and Center of Gravity with Right-Mounted Sidecar (letters A, B, and C map to Figure 3-7)
Frame
A
mm (in)
B
mm (in)
C
mm (in)
Weight
kg (lb)
Eaton 93PM-100-1 UPS with UPS Top Entry Wiring Sidecar (no breakers)
Capacity 844 (33.2 542 (21.3) 347 (13.7) 406 (894)
Redundant 847 (33.3) 542 (21.3) 346 (13.6) 411 (907)
Eaton 93PM-100-2 UPS with UPS Top Entry Wiring Sidecar (no breakers)
Capacity 911 (35.8) 541 (21.3) 338 (13.3) 469 (1034)
Redundant 913 (35.9 541 (21.3) 337 (13.3) 475 (1047)
Eaton 93PM-100-3 UPS with UPS Top Entry Wiring Sidecar (no breakers) Redundant 1001 (39.4) 541 (21.3) 330 (13.0) 539 (1188)
Eaton 93PM-100-1 UPS with four breaker SIAC-B
Capacity 855 (33.7) 568 (22.4) 367 (14.4) 433 (954)
Redundant 858 (33.8) 568 (22.4) 366 (14.4) 439 (967)
Eaton 93PM-100-2 UPS with four breaker SIAC-B Capacity 917 (36.1) 564 (22.2) 356 (14.0) 496 (1094)
Redundant 918 (36.1) 564 (22.2) 355 (14.0) 502 (1107)
Eaton 93PM-100-3 with four breaker SIAC-B Redundant 1001 (39.4) 561 (22.1) 346 (13.6) 566 (1248)
115.8
[4.56]
114.3
[4.50]
0.87
[0.22]
88.9
[3.50]
1.57
[0.40]
95.3
[3.57]
Front View
1/2" Knockout Pattern
(Typical 5 Sides
Needed to
remove key
(Square)
Dimensions are in millimeters [inches]