Eaton BladeUPS 5 kVA to 60 kVA (N+1) User’s Guide 164201649—Rev 14 139
Table 24. Electrical Input
BladeUPS 12 Model BladeUPS 12i Model BladeUPS 8 Model
BladeUPS 5.0
Model
Nominal Voltage 120/208V three-phase 230/400V three-phase 120/208V three-phase 120/208V three-phase
Nominal Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Frequency Range 45–65 Hz 45–65 Hz 45–65 Hz 45–65 Hz
Default Frequency Auto-detected Auto-detected Auto-detected Auto-detected
Rated Input Current 36A 24A 24A 16A
Connections
IEC 309-60A power
cord
IEC 309-32A power
cord
NEMA L21-30P NEMA L21-20P
Paralleling available for 12 kW or 12i kW
modules only. For paralleling, a single Anderson
input/output cord connects to the
BladeUPS Bar (see
).
BladeUPS 8 and BladeUPS 5.0 kW cannot be
paralled
NOTE: BladeUPS 8 kW can be upgraded in the
field to 12 kW in order to be paralleled for
additional capacity. Contact Eaton service for
details.
Noise Filtering MOVs and common mode line filter
Input Power Factor
High Efficiency setting: load dependent
Standard setting: >0.99
Input Mode Three-phase
Input Source
5-wire with continuous neutral.
NOTE: Contact your Eaton UPS sales specialist for operation with 4-pole ATS switches.
Table 25. Electrical Output
BladeUPS 12 Model
BladeUPS 12i
Model BladeUPS 8 Model
BladeUPS 5.0
Model
Nominal Output Voltage
120/208 Vac three-phase 230/400 Vac three-
phase
120/208V three-
phase
120/208V three-
phase
Output Voltage Variation
104–132 Vac phase to
neutral,
180–229 Vac phase to
phase
207–253 Vac phase
to neutral,
358–438 Vac phase
to phase
104–132 Vac phase
to neutral,
180–229 Vac phase
to phase
104–132 Vac phase
to neutral,
180–229 Vac phase
to phase
Connections
IEC 309-60A power cord IEC 309-32A power
cord
NEMA L21-30R NEMA L21-20R
Paralleling available for 12 kW or 12i kW
modules only. For paralleling, a single Anderson
input/output cord connects to the
BladeUPS Bar (see table 19 on Page 136 )
.
BladeUPS 8 and BladeUPS 5.0 kW cannot be
paralled
NOTE: BladeUPS 8 kW can be upgraded in
the field to 12 kW in order to be paralleled
for additional capacity. Contact Eaton service
for details.
Short Circuit Capability
(Battery Mode)
84A, <300 ms 44A, <300 ms 84A, <300 ms 84A, <300 ms
Specifications