61
Technical data
Mounting and Operating Instructions CEAG Central Battery System ZB-S 40071860179 (L) November 2018 www.ceag.de
S1
S2 S3
S4
C1
44
54
Test
FT
DT
A
B
A
B
+- +-
CG-S
RS485
24V Out
24V In
Z1
Z2 Z3
Z4
C0
14
12
24
22
34
32
1
23
Betriebs-
Sicherheitszwecke
bereit
Stromquelle für
Fehler
for Safety Services
Electrical Source
Ready
Failure
Esc.
Ok
CU
Control Unit
CLF
Q1
L1
L2
L3
L1
L3
L2
A
E18-Netz E18-Netz
L1
L2
L3
N
PE
L
N
-/N
+/L
U1
01
U2
02
A
B
+
-
PE
120Ohm
Mains
Electrical Souce
for Safety Source
F1-U
8AT
F1-0
8AT
F2-U
8AT
F2-0
8AT
Ein/On 1
Fehler/Failure 1
Ein/On 2
Fehler/Failure 2
Service
SOU S+ 2x4A
Switching over Unit
L
N
-/N
+/L
U1
01
U2
02
A
B
+
-
PE
120Ohm
Mains
Electrical Souce
for Safety Source
F1-U
8AT
F1-0
8AT
F2-U
8AT
F2-0
8AT
Ein/On 1
Fehler/Failure 1
Ein/On 2
Fehler/Failure 2
Service
SOU S+ 2x4A
Switching over Unit
CLFCLF
XXX
+++- --
SE
A
B
SE
A
B
X
B1
B2
T1T1
X
K1K1
XX
N
PE
L
24V
+-
EIN/ON
Störung
RS485
IN
Out
address
9
8
7
4
3
2
1
0
5
6
3
2
1
0
K2K2
X
NN
T2T2
LL
PEPE
Failure
(0)
T1
K1
K2
T2
- -
max.10A max.10A
TLS-BUS-Modul
2
1
S-4
123
4
5678
*L1
*L2 *L3
DLS
3PH
XXX
+++---
SE
A
B
SE
A
B
X
B1
B2
L
N
L
N
L
N
L
N
L
N
L
N
L
N
L
N
PEPE
123
4
5678
PE
DLS/3PH-BUS-Modul
24V
+-
EIN/ON
Störung/Failure
RS485
IN
Out
address
9
8
7
4
3
2
1
0
5
6
3
2
1
0
*=3PH
L1
L2
L3
N
PE
CLF
+
-
24V In
+
-
CCB
+
-
I
+
-
F
11
12
21 31
32
+
-
22
BST
Ein/On
Starkladung / Boost-Charge
Ladestörung / Charge-Failure
Service
ISO-Fehler / ISO-Failure
ISO-Test -
ISO-Test +
BCM
Battery Control Module
+
-
+
-
CM 1.7A DC
Charger Module
Ein/On
CCB
S2
S1
SKU CG-S 2x3A
F1L
F2L
F1-
F2-
Service
Störung/Failure
Ein/On
Netz
Mains
5AT
Netz
Mains
5AT
Batt.
5AT
+
Batt.
5AT
+
Batt.
5AT
-
Batt.
5AT
-
F1+
F2+
U1
01
U2
02
Störung/Failure
Ein/On
SKU CG-S 2x3A
F1L
F2L
F1-
F2-
Service
Störung/Failure
Ein/On
Netz
Mains
5AT
Netz
Mains
5AT
Batt.
5AT
+
Batt.
5AT
+
Batt.
5AT
-
Batt.
5AT
-
F1+
F2+
U1
01
U2
02
Störung/Failure
Ein/On
SKU CG-S 2x3A
F1L
F2L
F1-
F2-
Service
Störung/Failure
Ein/On
Netz
Mains
5AT
Netz
Mains
5AT
Batt.
5AT
+
Batt.
5AT
+
Batt.
5AT
-
Batt.
5AT
-
F1+
F2+
U1
01
U2
02
Störung/Failure
Ein/On
SKU CG-S 2x3A
F1L
F2L
F1-
F2-
Service
Störung/Failure
Ein/On
Netz
Mains
5AT
Netz
Mains
5AT
Batt.
5AT
+
Batt.
5AT
+
Batt.
5AT
-
Batt.
5AT
-
F1+
F2+
U1
01
U2
02
Störung/Failure
Ein/On
Q2
B+ B-
A
E18-Netz E18-Netz
L
N
B+
B-
CLF
3
Mains supply
General lighting
Emergency luminaires
DLS 3-Ph bus module
ZB-S system
Mains distribution box
Battery distribution box
CGVision
General power supply
Rental current meter
US-S/SOU2
1 5 9
4 8
3 7 11
2 6
10
2
9
10
4
11