146
4. Electro-Hydraulic Control Unit 01/2018 Rev. 1 EA(B)O-6X06
0044-18
0045-18
0047-18
4. Remove the motor with the plastic coupling sleeve with
the pump (detail).
Electric Motor Replacement
Disassembly
1. To remove the motor, rst remove the oil reservoir
[see Reservoir Replacement], always protecting with a
container the possible oil drip from the compartment.
2. Loosen the four bolts and remove the motor cap.
NOTE: Drain motor chamber oil.
0046-18
3. Loosen the two motor xing bolts.
NOTE: Check the condition of the plastic coupling
sleeve for cracks, marks and / or wear.