Serial Interface Operation
Eaton ePDU G3 Operation Manual P-164000277—Rev 1 www.eaton.com/ePDU 82
PDU.OutletSystem.Outlet[x].AutomaticRestart Parameter 0 : not restart at device startup
1 : should sequence back ON in line with
PDU.Outlet[u].RestartTimer
2 : should take the state the outlet had when power was
lost.
If the state was ON, should sequence back ON in line with
the outlet RestartTimer.
- RW
PDU.OutletSystem.Outlet[x].ChangedStatus.OverCurrent Timestamp s RO
PDU.OutletSystem.Outlet[x].ConfigCurrent Constant Nominal Amps: 10A, 15A, 16A, 20A, .. mA RO
PDU.OutletSystem.Outlet[x].Current Measure Current Measurement mA RO
PDU.OutletSystem.Outlet[x].DelayBeforeShutdown Command 0-n: Delayed shutoff
-1: Cancel / No action
When read, returns the downcount.
s RW
PDU.OutletSystem.Outlet[x].DelayBeforeStartup Command 0-n: Delayed restart
-1: Cancel / No action
When read, returns the downcount.
s RW
PDU.OutletSystem.Outlet[x].EWEntity.Importance Parameter Energy Wise Importance - RW
PDU.OutletSystem.Outlet[x].EWEntity.Keyword String[31] Energy Wise Keyword - RW
PDU.OutletSystem.Outlet[x].EWEntity.Level Parameter Energy Wise Level - RW
PDU.OutletSystem.Outlet[x].EWEntity.Role String[31] Energy Wise Role - RW
PDU.OutletSystem.Outlet[x].GangID Constant Breaker/section index where the Outlet is connected.
It is the x of Gang[x] collection.
- RO
PDU.OutletSystem.Outlet[x].iName String[31] Outlet friendly name. - RW
PDU.OutletSystem.Outlet[x].OutletID Constant Numbering of the outlet into the breaker/section module.
1 to 56.
- RO
PDU.OutletSystem.Outlet[x].OverCurrent[1].Threshold Parameter Threshold mA RW
PDU.OutletSystem.Outlet[x].OverCurrent[3].Threshold Parameter Threshold mA RW
PDU.OutletSystem.Outlet[x].OverCurrent[4].Threshold Parameter Threshold mA RW
PDU.OutletSystem.Outlet[x].PeakFactor Measure Crest factor of the current that is provided by the outlet. m% RO
PDU.OutletSystem.Outlet[x].PhaseID Constant Phase ID that powers the outlet:
- 1, 2, 3 to identify a simple phase.
- 12, 23, 31 to identify a composed phase.
- RO
PDU.OutletSystem.Outlet[x].PoleID Constant Pole ID of the breaker/section where the Outlet is
connected. Two cases are:
- Section or Single pole breaker, always 0.
- Double pole breaker:
0: when powered between 2 poles
1: when powered by pole 1 voltage.
2: when powered by pole 2 voltage.
- RO
PDU.OutletSystem.Outlet[x].PowerFactor Measure Power factor of the current provided by the phase.
Value 0 to 100 for Cos PHI = 0.00 to 1.00
m% RO
Table 8. ePDU CLI Objects (Continued)
XML Object Name Type Description Unit Access