VCS/VMS Auxiliary Section Removal and Disassembly | Auxiliary Section Service Procedures TRSM0940
Output Yoke Removal
1. Remove the two bolts that fasten the output Yoke to
the output shaft.
2. Remove the Output Yoke from the Output Shaft. A maul
or hammer may be required to apply force to the yoke
for removal.
Auxiliary Section Removal
1. Remove both Auxiliary Counter Shaft Bearing Covers.
Note: It is helpful to mark the covers to indicate which
position they are in as they will need to be reinstalled in
the same location.
2. Install Auxiliary Counter Shaft Support straps with 2-
3/8” NC x 1” and 1- 3/8”NCx1 1/2” clean capscrews.
Use the longer bolts to secure the center of each strap
as this will ensure the Auxiliary Countershafts will
remain in time.
Note: Do not use an air gun. Tighten by hand until the
screws are snug.