MHP/MXP/VHP/VXP Auxiliary Countershaft Installation | Auxiliary Section Service Procedures TRSM0940
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
Special Instructions
To assist in the Auxiliary Section Assembly, an Auxiliary
Section fixture can be made out of a 2” x 12’ piece of wood.
This fixture is designed to ease the assembly of the Auxil-
iary gearing. Set the Auxiliary Countershaft Front bearings
in the 3” holes to maintain the gearing positions when com-
bining with the Auxiliary Mainshaft Assembly.
Set the Assembled Auxiliary Mainshaft between the
Countershafts with the timing marks on all 3 sets of gearing
aligned.
Special Tools
RR1002TR Auxiliary Countershaft Support Straps
Bearing drivers
•Maul
Component Identification
None