TRSM0940 Removal and Installation | X-Y Shifter
X-Y Shifter Installation
1. Ensure Shift Blocks are in the Neutral position, then
move Shift Finger to the center (Neutral) location.
Note: If the Shift Finger is not properly aligned, the X-Y
Shifter will not fit properly at its mounting location.
2. Clean and remove old gasket material from Shift Bar
Housing. Then, install new gasket on the Shift Bar
Housing.
Note: Apply Eaton sealant part number 71205 or equiv-
alent to the mounting cap screws before installing.
3. The dowel pin on the X-Y Shifter must be aligned with
hole in the Shift Bar Housing.