TRSM0940 Appendix | Lubrication Specifications
Lubrication Specifications
Caution: Do not introduce additives and friction modifiers.
Caution: Never mix standard oils and synthetic transmis-
sion oils in the same transmission. When switching
between types of lubricants, all areas of each affected com-
ponent must be thoroughly drained.
Caution: Do not mix lubricants of different grades.
Note: For a list of Eaton Approved Synthetic Lubricants, see
TCMT0021 Roadranger Lubricant Products or call
1-800-826-HELP (4357).
Note: The use of lubricants not meeting these requirements
will affect warranty coverage.
Note: For lubrication change and inspection intervals, see
TCMT0021 Roadranger Lubricant Products.
Note: Please refer to CLSM0200 Eaton Heavy-Duty
Clutches for clutch lubrication and service guidelines.
Buy From a Reputable Dealer
For a complete list of approved and reputable dealers, write
to:
Eaton, Worldwide Marketing Services
P.O. Box 4013
Kalamazoo, MI 49003
Transmission Operating Angles
If the transmission operating angle is more than 12
degrees, or approximately a 21% grade, improper lubrica-
tion will occur. The operating angle is the transmission
mounting angle in the chassis plus the percent of upgrade
(expressed in degrees).
For operating angles over 12 degrees, the transmission
must be equipped with an oil pump or cooler kit to ensure
proper lubrication.
Transmission filters should be changed during regular
lubrication intervals. Inspection of the transmission filter
should be conducted during preventative maintenance
checks for damage or corrosion. Replace as necessary.
Operating Temperatures
Transmissions must not be operated at temperatures that
are consistently above 250°F (121°C). Operation at tem-
peratures above this limit causes loaded gear tooth tem-
peratures to exceed 350°F (177°C) which will ultimately
destroy the heat treatment of the gears.
The following conditions, in any combination, can cause
operating temperatures that exceed 250°F (120°C):
Operating consistently at high loads/slow speeds
High ambient temperatures
Restricted air flow around the transmission
Exhaust system too close to the transmission
High horsepower operation
Use of engine retarders
Maintenance and Lubricant Change
Intervals
Transmission inspections and lubricant changes are out-
lined below.
For a list of Eaton Roadranger-approved lubricants, see
TCMT0020 Roadranger Lubricant Products.
!
!
!
Interval Description
First 1,000 to
1,500 miles
Inspect oil levels. Check for leaks.
Every 2,500
miles
Inspect lubricant level. Perform
Transmission Inspection.
Every 5 years or
500,000 miles,
whichever
occurs first
Change oil and filters.