84
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
2022.10.7
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation | Auxiliary Section Service Procedures TRSM0940
3. Place Countershafts in the fixture or on a flat surface.
Turn the Countershafts until the two teeth marked on
each shaft are towards the middle.
4. Align the Auxiliary Mainshaft Assembly so the timing
marks on the Reduction Gear match up with the timing
marks on the 2 Auxiliary Countershafts. Also, align the
timing marks on the splitter gear to match time.
5. Install Range Yoke into the Synchronizer Sliding Slot.
Note: Ensure the Range Yoke offset side is facing
down.
6. Lay the Auxiliary Case Housing front on a clean flat
surface. Install the Bearing Race in the Bearing Bore.