128
Front Section Disassembly
4
Front Section 2nd Ed. 02/07 FSO-2405
FSO-2405/49
2mm
FSO-2405/48
2
Expansive Plugs
Installation
WARNING! Allways replace the removed
plug to prevent leaks.
1. With a clean rag and solvent, clean the plug
hole and remove any remaining sealant
compound. Do not use sand paper.
2. Apply sealant to the new plug and insert it into
the hole using the hands to guide the plug.
NOTE:
Apply
Eaton E677
to plugs.
3. Use the proper tool and a hammer to force the
plug into the plug bore. The proper depth is
when the plug is 2 mm below the plug bore
top.
NOTE: See “Special Tools”, Ref. E001020.
FSO-2405/170
3