Front Section Disassembly
4
FSO-2405 2nd Ed. 02/07 Front Section
Input Shaft Bearing Cup
Removal
1. Place the front housing properly supported
with the input shaft bearing cup removing side
down.
2. Use the bearing cup puller and remove the
bearing cup from the bearing bore.
NOTE: See “Special Tools”, Ref. E012004.
Installation
1. Support properly the front housing with bearing
cup installing side up.
2. Prior installing the bearing cup, carefully clean
bearing cup and bore.
3. Use the proper tool and drive the bearing cup
into the bearing bore, just until the cup be
guided by the bore.
NOTE: See “Special Tools”, Ref. E001033,
E001037, E001039
4. Install the input shaft bearing cover and tighten
the cover retaining capscrews to the proper
torque (see “Input Shaft Bearing Cover -
Installation”).
NOTE: Torque = 10-16 N.m (7-12 lb.ft)