149
Front Section Assembly
4
FSO-2405 2nd Ed. 02/07 Front Section
End Play Adjustment
Countershaft End Play Measurement
20. Choose one from housing threaded holes and
install the special plate (tool # E009001) to
support a dial indicator with magnetic base.
21. Install one from those removed transmission
capscrews in the hole at countershaft end
center. The capscrew head will be used as a
base to set the dial indicator tip.
22. Install the countershaft rear nut just a few
threads to support the pry bar (tool # E008001).
23. Rotate the countershaft several times in both
directions clockwise and counterclockwise to
make sure the countershaft is completely
seated on the bearing.
24. Set the dial indicator tip against the capscrew
head threaded in the countershaft end. Set the
pointer to zero.
25. Place the pry bar (tool # E008001) under the
countershaft nut and push the countershaft
upwards at once. Keep the countershaft in that
position while taking the dial indicator reading.
Record that reading.