4 CANopen communication settings
4.7 Parameters
CANopen for DA1, DC1, DE11 09/16 MN040019EN www.eaton.com 59
2086 P-34 PDP-Address rw RUN 1 ≙ 1 1 - 63 U16
2087 P-35 RS485-0 Baudrate rw RUN 1 ≙ 1 0 - 4 U16
2088 P-36 Comm Timeout Modbus RTU rw RUN 1 ≙ 1 0 - 8 U16
2089 P-37 Parameter Set rw STOP 1 ≙ 1 0 - 1 U16
208A P-38 Password Level2 rw RUN 1 ≙ 1 0 - 9999 U16
208B P-39 Parameter Lock rw RUN 1 ≙ 1 0 - 1 U16
208C
P-40 Action@Communication
Loss
rw STOP 1 ≙ 1 0 - 4 U16
208D
P-41 ParameterAccess rw RUN 1 ≙ 1 0 - 1 U16
2096 P-50 CAN0 Baudrate rw RUN 1 ≙ 1 0 - 3 U16
2097 P-51 RO1 Function rw RUN 1 ≙ 1 0 - 9 U16
2098 P-52 RO1 upper Limit rw RUN 100 ≙ 10.0 % 0 -2000 U16
2099 P-53 RO1 Switch-On Delay rw RUN 10 ≙ 1.0 s 0 - 250 U16
209A P-54 RO1 Hysteresis rw RUN 100 ≙ 10 % 0 - 1000 U16
CANOpen
Index [hex]
Para
meter
Designation Access Scale Value range Data
format
rw/
ro
RUN/
STOP