6 Technical Data
6.1 General rating data
DC1…20… and DC1…OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com 147
Motor feeder
Output voltage
DC1-1D… U
2
V 3~ 0 - 2 x U
e
(voltage doubler)
DC1-12…, DC1-32…, DC1-34… U
2
V 3~ 0 - U
e
Maximum length of motor cable l m 100 (shielded)
200 (unshielded)
Assigned motor output
at 230 V, 50 Hz P kW 0.37 - 4
at 400 V, 50 Hz P kW 0.75 - 22
Output Frequency
Range, parameterizable f
2
Hz 0 - 50/60 (max. 500 Hz)
resolution Hz 0.1
Rated operation current I
e
A 2.3 - 46
Overload current for 60 s every 600 s i
l
% 150
Overload current for 2.5 s every 600 s i
l
% 175
Switching frequency (double modulation) f
PWM
kHz max. 32
Operating mode
V/Hz control (speed accuracy) ±20 %, with slip compensation
Vector control
(static speed accuracy)
±0.033 %
±1% load range: 0 - 100 %
Torque response time t
r
ms 1 - 8
Torque linearity ±5 % (10 - 90 % of speed variable range,
20 - 100% of torque load range)
Response time (enable IGBT) t
r
ms < 10
DC braking
Time before start t s 0 - 25, in the event of a stop
Motor pick-up control function (for catching spinning
motors)
all frame sizes
Brake chopper only for sizes FS2 to FS4
Braking current during continuous operation % 100 (I
e
)
Maximum braking current % 150 for 60 s
Technical data Symbol Unit Value